Factory ChargedYes
-
Stages2
-
Refrigerant ControlEEV
-
Number of Compressor1
-
Start Kit Model Number (Field-Supplied)No
-
Fan Motor FLA0.71
-
MCA15
-
MaterialGalvanized Steel
-
Fan TypePropeller
-
Motor Power Rating208-230V/3Phase/60Hz
-
Motor HP1/8
-
StageCapacityNot Available
-
CommunicatingNon-communicating
-
Compressor Insulation/Sound BlanketNo
-
ElecHertz60
-
Motor (RPM)825
-
Compressor Power Rating208-230V/1Phase/60Hz
-
Min SEER15
-
FAN MOTOR HP1/8
-
Power Supply208-230V/3Phase/60Hz
-
Max SEER18
-
Energy Star CompliantNo
-
Fan DriveDirect
-
HSPF8.2
-
TableSH-11-A
-
TierXR17
-
HSPF2Not Available
-
Shipping Weight307.0
-
StandardsAHRI, cUL US
-
Number of Phase3
-
SEER17
-
Insulation MaterialNon-insulated
-
Compressor TypeScroll
-
Number of Fan Motors1
-
Coil TypeSpine Fin
-
Compressor Sump Heater Factory InstalledYes
-
Tonnage3
-
Voltage208-230V
-
Model-Phase3
-
Refrigerant Charge lbs9 lbs-3 Oz.
-
Actual Height45.125
-
BTUH36,000
-
Compressor RLA11.6
-
Blower Fan Speeds1
-
Coil Face Area (Sq-Ft)30.79
-
Actual Dimension UOMin
-
Number of Fans1
-
Max Fuse25A
-
Charging Specification Subcooling9 Deg. F
-
ElecVolts208-230V
-
Nominal Capacity BTU Rating36,000
-
SEER2Not Available
-
Refrigerant TypeR-410A
-
Split System ConnectionBrazed
-
FPI24
-
Capacity (Kg)3,048.14
-
Airflow CFM3,700
-
ElecPhases3
-
Compressor LRA73
-
Full Octave Sound Power[dB]74 at 63Hz, 71 at 125Hz, 72 at 250Hz, 70 at 500Hz, 69 at 1000Hz, 62 at 2000Hz, 59 at 4000Hz, 55 at 8000Hz
-
Sound Level (dB)72
-
Actual Width37.25
-
Sound Rating (dB)72 dB(A)
-
Frequency (Hz)60
-
Outdoor Coil-Tube Size (In)3/8
-
Heating CapacityNot Available
-
Coil Rows1
-
Blower Motor TypeDirect Drive
-
Uncrated Dimensions (HxWxD)45.13 X 37.25 X 34.25 in.
3 TON 230V 3PHASE R410 2-STG SPLIT HP
$9,551.00 Original price was: $9,551.00.$5,796.00Current price is: $5,796.00.
-
4TWA7036A3000A
XR17 R-410A Split System Two Stage Heat Pump, 208-230/3/60, 36K BTUH
Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). (i) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate.
10 in stock
Weight | 307 lbs |
---|---|
Dimensions | 37.90 × 35 × 49.90 in |
Only logged in customers who have purchased this product may leave a review.
Reviews