SEER17
-
BTUH45,000
-
FAN MOTOR HP1/4
-
Fan Motor FLA1.30
-
MaterialGalvanized Steel
-
Energy Star CompliantNo
-
ElecPhases3
-
Motor (RPM)825
-
Split System ConnectionBrazed
-
Airflow CFM4,760
-
Number of Fans1
-
Power Supply208-230V/3Phase/60Hz
-
Compressor Insulation/Sound BlanketNo
-
Outdoor Coil-Tube Size (In)3/8
-
FPI24
-
Sound Level (dB)74
-
StandardsAHRI, cUL US
-
TierXR17
-
Coil TypeSpine Fin
-
Refrigerant Charge lbs12 lbs-10 Oz.
-
Uncrated Dimensions (HxWxD)45.13 X 37.25 X 34.25 in.
-
Coil Face Area (Sq-Ft)29.15
-
HSPF8.5
-
Model-Phase3
-
Compressor TypeScroll
-
Actual Height45.125
-
Refrigerant TypeR-410A
-
Motor Power Rating208-230V/3Phase/60Hz
-
Motor HP1/4
-
Compressor RLA16.2
-
Charging Specification Subcooling10 Deg. F
-
Tonnage5
-
Max Fuse35A
-
MCA22
-
HSPF2Not Available
-
Compressor Power Rating208-230V/1Phase/60Hz
-
Actual Width37.25
-
Fan TypePropeller
-
Number of Compressor1
-
Heating CapacityNot Available
-
Nominal Capacity BTU Rating60,000
-
Min SEER15.5
-
ElecVolts208-230V
-
Number of Phase3
-
Blower Fan Speeds1
-
Full Octave Sound Power[dB]75 at 63Hz, 71 at 125Hz, 71 at 250Hz, 71 at 500Hz, 70 at 1000Hz, 65 at 2000Hz, 58 at 4000Hz, 52 at 8000Hz
-
ElecHertz60
-
Insulation MaterialNon-insulated
-
TableSH-11-A
-
Factory ChargedYes
-
Compressor LRA110
-
Number of Fan Motors1
-
SEER2Not Available
-
Start Kit Model Number (Field-Supplied)No
-
Coil Rows2
-
CommunicatingNon-communicating
-
Sound Rating (dB)74 dB(A)
-
Capacity (Kg)5,080.23
-
Refrigerant ControlEEV
-
Actual Dimension UOMin
-
Voltage208-230V
-
Max SEER16.5
-
StageCapacityNot Available
-
Blower Motor TypeDirect Drive
-
Stages2
-
Frequency (Hz)60
-
Compressor Sump Heater Factory InstalledYes
-
Shipping Weight326.0
-
Fan DriveDirect





5 TON 230V 3PHASE R410 2-STG SPLIT HP
$11,575.00 Original price was: $11,575.00.$6,940.00Current price is: $6,940.00.
-
4TWA7060A3000A
XR17 R-410A Split System Two Stage Heat Pump, 208-230/3/60, 60K BTUH
5 TON 230V 3PHASE R410 2-STG SPLIT HP
Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). (i) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate.
10 in stock
Weight | 326 lbs |
---|---|
Dimensions | 37.90 × 35 × 49.90 in |