Tonnage4
-
Voltage460V
-
StandardsAHRI, cUL US
-
Fan Motor FLA0.60
-
Stages2
-
Heating CapacityNot Available
-
Factory ChargedYes
-
Model-Phase3
-
Actual Height45.125
-
StageCapacityNot Available
-
Blower Fan Speeds1
-
Airflow CFM4,260
-
Number of Compressor1
-
Frequency (Hz)60
-
Max SEER18
-
Compressor TypeScroll
-
Coil TypeSpine Fin
-
Motor Power Rating460V/1Phase/60Hz
-
Full Octave Sound Power[dB]85 at 63Hz, 74 at 125Hz, 68 at 250Hz, 69 at 500Hz, 69 at 1000Hz, 63 at 2000Hz, 58 at 4000Hz, 54 at 8000Hz
-
Motor HP1/5
-
Number of Fans1
-
Number of Phase3
-
MCA9
-
Energy Star CompliantNo
-
Charging Specification Subcooling8 Deg. F
-
ElecPhases3
-
Uncrated Dimensions (HxWxD)45.13 X 37.25 X 34.25 in.
-
Number of Fan Motors1
-
Fan DriveDirect
-
HSPF10
-
Compressor Power Rating460V/3Phase/60Hz
-
Coil Rows2
-
Capacity (Kg)4,064.19
-
MaterialGalvanized Steel
-
Min SEER16
-
Compressor Insulation/Sound BlanketNo
-
Blower Motor TypeDirect Drive
-
SEER17
-
Compressor Sump Heater Factory InstalledYes
-
Fan TypePropeller
-
SEER2Not Available
-
Compressor RLA6.4
-
Start Kit Model Number (Field-Supplied)No
-
Refrigerant TypeR-410A
-
FAN MOTOR HP1/5
-
Nominal Capacity BTU Rating48,000
-
ElecHertz60
-
Refrigerant ControlEEV
-
ElecVolts460V
-
Outdoor Coil-Tube Size (In)3/8
-
HSPF2Not Available
-
Coil Face Area (Sq-Ft)29.15
-
Split System ConnectionBrazed
-
BTUH48,000
-
TableSH-11-A
-
TierXR17
-
Shipping Weight323.0
-
Compressor LRA41
-
FPI24
-
Sound Level (dB)73
-
Power Supply460V/3Phase/60Hz
-
CommunicatingNon-communicating
-
Insulation MaterialNon-insulated
-
Sound Rating (dB)73 dB(A)
-
Actual Width37.25
-
Actual Dimension UOMin
-
Max Fuse15A
-
Motor (RPM)825
-
Refrigerant Charge lbs12 lbs-9 Oz
XR17 R-410A Split System Two Stage Heat Pump, 460/3/60, 48K BTUH Nom Cap
$10,664.00 Original price was: $10,664.00.$6,500.00Current price is: $6,500.00.
-
Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). (i) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate.
9 in stock
Weight | 330 lbs |
---|---|
Dimensions | 37.90 × 35 × 49.90 in |
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.