Frequency (Hz)60
-
TierXR17
-
StageCapacityNot Available
-
Actual Dimension UOMin
-
Voltage460V
-
Number of Fan Motors1
-
Factory ChargedYes
-
ElecHertz60
-
Coil Face Area (Sq-Ft)29.15
-
Power Supply460V/3Phase/60Hz
-
Stages2
-
Coil TypeSpine Fin
-
Sound Level (dB)74
-
Full Octave Sound Power[dB]75 at 63Hz, 71 at 125Hz, 71 at 250Hz, 71 at 500Hz, 70 at 1000Hz, 65 at 2000Hz, 58 at 4000Hz, 52 at 8000Hz
-
Shipping Weight326.0
-
Uncrated Dimensions (HxWxD)45.13 X 37.25 X 34.25 in.
-
Compressor RLA7.6
-
MCA10
-
Max SEER16.5
-
Split System ConnectionBrazed
-
Heating CapacityNot Available
-
Airflow CFM4,760
-
Nominal Capacity BTU Rating60,000
-
ElecPhases3
-
Capacity (Kg)5,080.23
-
StandardsAHRI, cUL US
-
Start Kit Model Number (Field-Supplied)No
-
Number of Compressor1
-
Insulation MaterialNon-insulated
-
Compressor Power Rating460V/3Phase/60Hz
-
HSPF2Not Available
-
Compressor TypeScroll
-
FAN MOTOR HP1/4
-
Sound Rating (dB)74 dB(A)
-
Fan DriveDirect
-
Coil Rows2
-
SEER17
-
HSPF8.5
-
Number of Phase3
-
Min SEER15.5
-
Actual Height45.125
-
Refrigerant ControlNot Available
-
Refrigerant TypeR-410A
-
Refrigerant Charge lbs12 lbs-10 Oz.
-
Motor (RPM)830
-
TableSH-11-A
-
Motor HP1/4
-
Blower Motor TypeDirect Drive
-
Max Fuse15A
-
MaterialGalvanized Steel
-
Tonnage5
-
Energy Star CompliantNo
-
Compressor Sump Heater Factory InstalledYes
-
Model-Phase3
-
Outdoor Coil-Tube Size (In)3/8
-
Actual Width37.25
-
ElecVolts460V
-
Motor Power Rating460V/1Phase/60Hz
-
Fan TypePropeller
-
Charging Specification Subcooling10 Deg. F
-
Compressor Insulation/Sound BlanketNo
-
BTUH58,000
-
Fan Motor FLA0.72
-
Compressor LRA52
-
CommunicatingNon-communicating
-
Blower Fan Speeds1
-
Number of Fans1
-
SEER2Not Available
-
FPI24
5 TON 460V 3PHASE R410 2-STG SPLIT HP
$11,675.00 Original price was: $11,675.00.$6,425.00Current price is: $6,425.00.
-
4TWA7060A4000A
XR17 R-410A Split System Two Stage Heat Pump, 460/3/60, 60K BTUH
Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship-with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). (i) The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Always verify proper system charge via subcooling (TXV/EEV) or superheat (fixed orifice) per the unit nameplate.
10 in stock
Weight | 326 lbs |
---|---|
Dimensions | 37.90 × 35 × 49.90 in |
Only logged in customers who have purchased this product may leave a review.